Alarm Clock

Creates a pulse on output (Aon) at a preset time.
A snooze function is also integrated.
In addition to individual days of the week, you can define your own alarm times for the operating modes "Public Holiday", "Vacation", and "School Holidays/Day off".
For the operating modes either corresponding operating times must be created or the output of the respective operating mode must be activated via a program logic.

Table of Contents


Inputs

Abbreviation Summary Description Unit Value Range
Ca Confirm alarm - 0/1
S Start snooze timer Pulse sets output (Buzzer) to 0 and starts snooze timer for the duration of parameter (Sd).
Another pulse during an active snooze timer restarts the timer.
- 0/1
DisA Disable alarm entries Disables all alarm entries. - 0/1
Tg Toggle Enables / disables the alarm entry 'Default alarm'.
A pulse during an active alarm ends the alarm.
- 0/1
Set Set alarm time for default alarm Defined by minutes past midnight (E.g. 360 min = 06:00am) min 0...1439
Rtd Reset to default Resets parameters and settings of the block to the default values as specified in the block preset. - 0/1
Off Off Pulse: Outputs are reset / switched off.
On: Block is locked.
Dominating input.
The name of the connected sensor is used in the user interface.
- 0/1




Outputs

Abbreviation Summary Description Unit Value Range
Aon Pulse on alarm start - 0/1
Aoff Pulse on alarm end - 0/1
Buzzer Buzzer ON when alarm sound is active.
OFF during snooze time.
- 0/1
A Alarm ON when alarm is active. - 0/1
Pa Pre-alarm Outputs a pulse before the alarm.
Start time set via parameter (Pat).
- 0/1
Rst Remaining snooze time s 0...∞
Da Default alarm state On, when alarm entry 'Default alarm' is enabled. - 0/1
Tna Time of next alarm Outputs date and time of the next alarm - -
AC API Connector Intelligent API based connector.
API Commands
- -




Parameters

Abbreviation Summary Description Unit Value Range Default Value
Rem Remanence input Remanence input: If active, the function block retains its previous state after a Miniserver reboot.
The state of the function block is saved:
– When saving to the Miniserver
– At a planned reboot
– Before a backup
– Once per hour
The data is saved on the SD card.
- 0/1 0
MaxA Maximum alarm duration Ends alarm after set time.
If setting "Confirmation required" is activated, the snooze timer starts after the alarm duration has expired.
s 0...∞ 120
Pat Pre-alarm time Time that the pre-alarm is started before the alarm. s 0...∞ 180
Sd Snooze duration Snooze duration until the alarm sound is restarted. s 60...1800 300
Bri Touch Nightlight display brightness inactive
This parameter is only visible in certain configurations.
% 0...100 1
Bra Touch Nightlight display brightness active
This parameter is only visible in certain configurations.
% 0...100 50
As Alarm sound (Touch Nightlight) 1: Deep 4-way beep
2: High 4-way beep
3: Deep 2-way beep
4: High 2-fold beep
5: Siren
This parameter is only visible in certain configurations.
- 1...5 1
Asv Alarm sound volume (Touch Nightlight)
This parameter is only visible in certain configurations.
% 5...100 100
Asf Alarm sound fade-in (Touch Nightlight) 1 = Alarm sound fades in for the duration of 60 seconds.
0 = No fade-in
This parameter is only visible in certain configurations.
- 0/1 0




Properties

Summary Description Default Value
Alarm settings Edit Alarms -
Acknowledgement required After the alarm the snooze timer starts automatically until it is acknowledged -




Set alarm time

With the green cross or eraser, alarm times can be added and removed. The alarm time can be defined directly in the settings menu, but also in the user interface.