Hello,
I have a Loxone Touch sensor (Item No.: 100221) used with Loxone Miniserver (version: 10.3.11.27).
The touch inputs are work one the good way.
Also the temperature and the humidity sensor works.
But when I try to use the followings:
Settings –> Display error input [yes]
Receive –> Validation timeout: 180
Validation –> Default value: -127 (or 0)
After a while there is an error. That Temperature or Humidity "block" of that touch sensor will be red and the output say this: 26,5°>-127° for example at the temperture. The 26,5 is the previous value and the -127 (or 0) is that I already set previously for the "Default" value at the Validation section.
And when I blew to the sensor and the temperature and the humidity are changing, the error is disappearing for a while.
Meanwhile the touch inputs are work if I try it them.
I would like to know if there is a problem with a sensor.
With the same setting the 1-wire sensors 8DS18B20) are work properly.
What will be the problem?
Hi Karoly
There is nothing wrong with your sensor. As both the temperature and humidity are analogue they will resend values either within a specific time frame or on a rapid change, hence why when you blow on it, it then works. Quite simply 180 seconds is too short for the validation timeout, in this space of time the temperature and humidity of the space won’t have changed and therefore a new value won’t have been sent.
For validation timeouts I would recommend a much longer period of time, such as 3600 seconds (1 hour). Also I would recommend your default value to be a high number not a low one as this will make your heating come on and stay on permanently. For example I use 33.33 as my validation timeouts, this then prevents any unnecessary triggering of the heating and within the app is still obvious that the default value has occurred.
KR
Hugh
 | Monday | Tuesday | Wednesday | Thursday | Friday |
---|---|---|---|---|---|
0830-0900 | Welcome | Arrival and Exchange | Arrival and Exchange | Arrival and Exchange | Arrival and Exchange |
Unit 1 | Easy Lighting Planning Square meter formulas. Room types, Direct/Indirect |
Automatic Basic Lighting Presence Sensor Air/Tree |
Shading & Automation Controls vs Automation  configuration shading types |
Multiroom Audio System, scaling, simple audio planning |
Media controller IR and RS Protocols, AVR |
Unit 2 | Intuitive Operating Concept Room types & moods |
Presence Optimization Exercises by type of room |
System Protection Functions Storm, frost, privacy, break-in |
Cabling & Configuration Audioserver Extension speaker |
Operating Concept Specific Operating modes, Touch Pure Flex |
Unit 3 | Configuration Room Types Basic Configuration |
Presence Areas Practice P/1-8 |
Optimise Protection Functions Practical exercises by type |
Operation & Connections Line In/Out, SPDIF Signal converter |
Optimise Conference Room Control and programming |
1200 | Lunch Break | Lunch Break | Lunch Break | Lunch Break | Lunch Break & wrap up |
Unit 4 | Lighting Controller In-depth T5/1-8, lC1-4, M+/-, Mix |
Technologies Dali, DMX, PWM |
Weather & Sunshine Weather station & forecasts |
Smart Home Functions TTS, Announcements, Bell |
 |
Unit 5 | Operating Concept Advanced Exercise by type of room |
Daylight Control HCL Practical implementation |
Automatic Sun Position Control Protection types IR/UV/Lux |
HiFi and Ambient Sound Signum and Install 7 |
 |
Unit 6 | Operating Concept Specific     Hotel, Office, Auditorium | Constant Light Control Measurement, control, implementation |
Automatic Sun Position Control Optimization of parameters |
Acoustics & Sound Optimization   Optimize audio planning |  |
Unit 7 | Touch Pure Flex Scrolling text, master brightness |
Signalization via Light Practice example |
Operating Concept Specific Practical examples | Audioserver in combination   Exercises Lan/Tree Turbo |  |
Booking Request for CPD
Please complete the following details as part of your request to book this CPD.
Once we have received your details, we will be in touch to discuss your request further.
From your first enquiry to the finishing touches on your project, Loxone and your Loxone Partner will be with you all the way. Benefit from the experience that we have gained through the realisation of over one hundred thousand projects worldwide to ensure your project exceeds your expectations.