Creates a pulse on output (Aon) at a preset time.
A snooze function is also integrated.
In addition to individual days of the week, you can define your own alarm times for the operating modes "Public Holiday", "Vacation", and "School Holidays/Day off".
For the operating modes either corresponding operating times must be created or the output of the respective operating mode must be activated via a program logic.
Table of Contents
Inputs↑
Abbreviation | Summary | Description | Unit | Value Range |
---|---|---|---|---|
Ca | Confirm alarm | - | 0/1 | |
S | Start snooze timer | Pulse sets output (Buzzer) to 0 and starts snooze timer for the duration of parameter (Sd). Another pulse during an active snooze timer restarts the timer. |
- | 0/1 |
DisA | Disable alarm entries | Disables all alarm entries. | - | 0/1 |
Tg | Toggle | Enables / disables the alarm entry 'Default alarm'. A pulse during an active alarm ends the alarm. |
- | 0/1 |
Set | Set alarm time for default alarm | Defined by minutes past midnight (E.g. 360 min = 06:00am) | min | 0...1439 |
Rtd | Reset to default | Resets parameters and settings of the block to the default values as specified in the block preset. | - | 0/1 |
Off | Off | Pulse: Outputs are reset / switched off. On: Block is locked. Dominating input. The name of the connected sensor is used in the user interface. |
- | 0/1 |
Outputs↑
Abbreviation | Summary | Description | Unit | Value Range |
---|---|---|---|---|
Aon | Pulse on alarm start | - | 0/1 | |
Aoff | Pulse on alarm end | - | 0/1 | |
Buzzer | Buzzer | ON when alarm sound is active. OFF during snooze time. |
- | 0/1 |
A | Alarm | ON when alarm is active. | - | 0/1 |
Pa | Pre-alarm | Outputs a pulse before the alarm. Start time set via parameter (Pat). |
- | 0/1 |
Rst | Remaining snooze time | s | 0...∞ | |
Da | Default alarm state | On, when alarm entry 'Default alarm' is enabled. | - | 0/1 |
Tna | Time of next alarm | Outputs date and time of the next alarm | - | - |
AC | API Connector | Intelligent API based connector. API Commands |
- | - |
Parameters↑
Abbreviation | Summary | Description | Unit | Value Range | Default Value |
---|---|---|---|---|---|
Rem | Remanence input | Remanence input: If active, the function block retains its previous state after a Miniserver reboot. The state of the function block is saved: – When saving to the Miniserver – At a planned reboot – Before a backup – Once per hour The data is saved on the SD card. |
- | 0/1 | 0 |
MaxA | Maximum alarm duration | Ends alarm after set time. If setting "Confirmation required" is activated, the snooze timer starts after the alarm duration has expired. |
s | 0...∞ | 120 |
Pat | Pre-alarm time | Time that the pre-alarm is started before the alarm. | s | 0...∞ | 180 |
Sd | Snooze duration | Snooze duration until the alarm sound is restarted. | s | 60...1800 | 300 |
Bri | Touch Nightlight display brightness inactive | This parameter is only visible in certain configurations. |
% | 0...100 | 1 |
Bra | Touch Nightlight display brightness active | This parameter is only visible in certain configurations. |
% | 0...100 | 50 |
As | Alarm sound (Touch Nightlight) | 1: Deep 4-way beep 2: High 4-way beep 3: Deep 2-way beep 4: High 2-fold beep 5: Siren This parameter is only visible in certain configurations. |
- | 1...5 | 1 |
Asv | Alarm sound volume (Touch Nightlight) | This parameter is only visible in certain configurations. |
% | 5...100 | 100 |
Asf | Alarm sound fade-in (Touch Nightlight) | 1 = Alarm sound fades in for the duration of 60 seconds. 0 = No fade-in This parameter is only visible in certain configurations. |
- | 0/1 | 0 |
Properties↑
Summary | Description | Default Value |
---|---|---|
Alarm settings | Edit Alarms | - |
Acknowledgement required | After the alarm the snooze timer starts automatically until it is acknowledged | - |
Set alarm time↑
With the green cross or eraser, alarm times can be added and removed. The alarm time can be defined directly in the settings menu, but also in the user interface.