Up to 8 radio buttons, only one output can be active at a time. E.g. pulse at input (I3) activates output (O3).
Table of Contents
Inputs↑
Abbreviation | Summary | Description | Value Range |
---|---|---|---|
I1-8 | Input 1-8 | Switches the respective output 1-8 On | 0/1 |
+ | Next output | 0/1 | |
- | Previous output | 0/1 | |
Sel | Select output | Switches to specific output. | ∞ |
Off | Off | Pulse: Outputs are reset / switched off. On: Block is locked. Dominating input. The name of the connected sensor is used in the user interface. |
0/1 |
DisPc | Disable periphery control | Disables all inputs when On. (e.g Child lock, cleaning) Control via user interface is still possible. |
0/1 |
Outputs↑
Abbreviation | Summary | Description | Value Range |
---|---|---|---|
O1-8 | Output 1-8 | 0/1 | |
N | Number of active output | ∞ | |
AC | API Connector | Intelligent API based connector. API Commands |
- |
Parameters↑
Abbreviation | Summary | Description | Value Range | Default Value |
---|---|---|---|---|
Rem | Remanence input | Remanence input: If active, the function block retains its previous state after a Miniserver reboot. The state of the function block is saved: – When saving to the Miniserver – At a planned reboot – Before a backup – Once per hour The data is saved on the SD card. |
0/1 | 0 |
Max | Max. outputs | Maximum number of selectable outputs. Example: Max=4 -> only outputs 1-4 can be activated via block inputs. In the user interface, all labeled outputs can be activated regardless of this setting. |
1...8 | 8 |
Sk0 | Skip 0 | 'All-off' (0) is skipped when switching with +/- when On. Applies only to object inputs, not to the buttons in the user interface. |
0/1 | 0 |
Properties↑
Summary | Description | Default Value |
---|---|---|
Edit outputs | Edit output names | - |
Labelling Outputs↑
Outputs can be labeled by double-clicking on the block.
Labeled outputs are also displayed in the user interface and can be activated there.