Delayed ON and OFF switching of the output
Table of Contents
Inputs↑
Abbreviation | Summary | Description | Value Range |
---|---|---|---|
Tr | Trigger | 0/1 | |
Off | Off | Pulse: Outputs are reset / switched off. On: Block is locked. Dominating input. |
0/1 |
Outputs↑
Abbreviation | Summary | Value Range |
---|---|---|
O | Output | 0/1 |
Parameters↑
Abbreviation | Summary | Description | Unit | Value Range | Default Value |
---|---|---|---|---|---|
Rem | Remanence input | Remanence input: If active, the function block retains its previous state after a Miniserver reboot. The state of the function block is saved: – When saving to the Miniserver – At a planned reboot – Before a backup – Once per hour The data is saved on the SD card. |
- | 0/1 | 0 |
Don | Duration switch-on delay | Delay duration before the output is switched ON, when input is On | s | 0...∞ | 1 |
Doff | Duration switch-off delay | Delay until the output switches to OFF with a falling edge at trigger | s | ∞ | 1 |
Timing Diagram↑