Selection Switch (+)

A pulse on input (+) increases the value on output (O) by the step size (Sts). When (Vmax) is reached, it starts again at (Vmin).
A long-click on (+) increases the value on output (O) every (Rr) seconds.

Table of Contents


Inputs

Abbreviation Summary Description Value Range
+ Value+ Increases the value at output (O) by the step size (Sts). When (Vmax) is reached, it starts again at (Vmin). 0/1
Val Set value Sets a specific value on output (O).
Off Off Pulse: Output (O) is reset to the default value (Vdef).
On: Block is locked.
Dominating input.
The name of the connected sensor is used in the user interface.
0/1
DisPc Disable periphery control Disables all inputs when On. (e.g Child lock, cleaning)
Control via user interface is still possible.
0/1




Outputs

Abbreviation Summary Description Value Range
O Output
AC API Connector Intelligent API based connector.
API Commands
-




Parameters

Abbreviation Summary Description Unit Value Range Default Value
Rem Remanence input Remanence input: If active, the function block retains its previous state after a Miniserver reboot.
The state of the function block is saved:
– When saving to the Miniserver
– At a planned reboot
– Before a backup
– Once per hour
The data is saved on the SD card.
- 0/1 0
Vmin Minimum value - 1
Vmax Maximum value - 10
Sts Step size - 1
Rr Repetition rate Long-click on (+) increases the value on output (O) every (Rr) seconds. s 0...∞ 0,2
Vdef Default value Default value when input (Off) is triggered. - 1




Timing Diagram