Smart Socket Air

The Smart Socket Air is a switchable socket with measurement of temperature, power and energy, based on Loxone Air technology.

Datasheet Smart Socket Air

Table of Contents


Commissioning

In delivery state, pairing mode will be active after plugging the device into a socket. This is indicated by the status LED flashing red/green/orange.

Then follow the pairing procedure on the Air Interface.

To activate the pairing mode manually, hold down the pairing button for at least 5 seconds immediately after plugging the device in. The pairing button is located on the front of the device:


Status LED

A detailed listing of the different LED states can be found here.

In normal operation the status LED is off. Please note, however, that the status LED can also be controlled via the output in the programming.


Country variants / Connector types

Typ F – Item 100115

Germany, Austria, Afghanistan, Algeria, Andorra, Bosnia-Herzegovina, Bulgaria, Croatia, Estonia, Finland, Greece, Hungary, Indonesia, Iceland, Italy/San Marino/Vatican City State, Korea, Latvia, Lithuania, Luxembourg, Macedonia, Montenegro, Moldova, Netherlands, Norway, Portugal, Romania, Russia, Sweden, Serbia, Slovenia, Spain, Syria, Turkey, Ukraine

Typ J – Item 100119

Switzerland, Liechtenstein, Maldives, Madagascar, Rwanda, Ethiopia, El Salvator, Jordan

Typ E – Item 100120

France, Belgium, Monaco, Czech Republic, Slovakia, Tunisia, many former French colonies

Typ G – Item 100121

Great Britain, Bahrain, Bangladesh, Belize, Bhutan, Botswana, Brunei, Cambodia, Channel Islands, Cyprus, Dominica, El Salvator, Falkland Islands, Gambia, Guatemala, Guyana, Hong Kong, Ireland, Isle of Man, Kenya, Kuwait, Lebanon, Macau, Malawi, Malaysia, Maldicia, Malta, Mauritius, Myanmar, Nigeria, Oman, Seychelles, Tanzania, Singapore


Sensors

Summary Description Unit Value Range
Temperature Provides the measured value of the temperature sensor:
Every 5 min.
° -40...125
Power Provides the value of the current power:
Above 5% and min. 2W change from the last value, at most every 5 sec.
Otherwise every 5 min and when the load is switched off.
kW 0...4
Energy Provides the consumed energy since the last value:
Every 5 min and when the load is switched off.
kWh 0...∞
Input 1 Digital input to use the button (pairing button) - 0/1




Actuators

Summary Description Value Range
Relay Output to switch the connected load 0/1
Status LED Analog output to control the status LED. 0=Off 1=Green 2=Orange 3=Red 0...3




Diagnostic Inputs

Summary Description Unit Value Range
Online Status Smart Socket Air Indicates whether the device can be reached by the Miniserver.
Diagnostics for Air devices
Diagnostics for Tree devices
Diagnostics for Extensions
Digital 0/1
System temperature Provides the internal device temperature.
This is often the temperature of the CPU or another location in the device.
°




Properties

Summary Description Default Value
Monitor online status When selected, you will be notified via System Status or the Mailer if the device is no longer available or goes offline. -
Serial number Serial number of Air device -
Device type Air device type -
Application Specifies the intended use of the actuators.
Universal: Outputs can be used freely.
Load: Switch any load. Auto-Configuration will create a Switch.
Lighting: Control lighting. Will be connected to Lighting Controller by Auto-Configuration.
-




Safety Instructions

Warning! Before using the product, please follow the safety instructions below. These serve to prevent hazards and personal injury and property damage.
  • If the case or the power contacts are damaged, do not operate the Smart Socket Air.

  • The Smart Socket Air may only be operated in closed, dry rooms.

  • To prevent the risk of fire or electric shock, protect the Smart Socket Air from moisture, rain, and heat.

  • The maximum load capacity of the Smart Socket is 13A. When connecting devices, make sure that this value is not exceeded.

  • Devices without a cable connection that perform mechanical movements or vibrations must not be connected directly to the Smart Socket Air.

  • Cleaning and maintenance work may only be carried out with the mains plug disconnected.

  • The Smart Socket Air must not be opened.

  • Keep the Smart Socket Air away from children.

  • This device may be used by children 8 years old and over, and by persons with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge, if they have been supervised or instructed in the safe use of the device and understand the hazards arising therefrom. Children are not allowed to play with the device. Cleaning and maintenance must not be carried out by children.

  • Failure to follow the safety instructions may result in damage to the Smart Socket Air and personal injury.

  • Use the Smart Socket Air only as directed.

  • The Smart Socket Air must not be inserted one behind the other.

  • The Smart Socket Air needs to be positioned near the device and easily accessible.


Documents

Datasheet Smart Socket Air

Thermal Shutdown Temperatures